OM-USB-1208 ULx install Labview17

When I run the ULxForLabVIEW installer, I get the error "LabVIEW 2010 or later is required for this package".I have installed and licensed Labview 2017 32 bit version and am running Windows 7InstaCal...

View Article


USB-6221 MTBF

I'm trying to find MTBF estimates for USB-6221 or related product. This is desired by our U.S. Government customer. Appreciate any information that might help.

View Article


NI PCIe-6509 I/O question

I was wondering if, for the NI PCIe6509, the lines can be changed as input/output on the run, meaning, if initially I set some lines as input I can change them to be outputs while I'm running a...

View Article

Using an External Digital Trigger to Read Digital Input Once

Hello, I am using the NI USB X Series (specifically the NI USB-6343) and programming in Visual studio 2010 with C# .NET . What I have been trying to do is use an external Digital trigger on Port 1...

View Article

How to input the information of load cell and rotary encoder into eZ-Analyst...

I would need to input the information of a load cell and a rotary encoder, which are connected to channels of IOTech 650U, to the eZ-Analyst software. I have the following information...

View Article


Image may be NSFW.
Clik here to view.

Digital Input as a Counter ... How to do it please help

Hi,Im new to the LavView programming and i have an NI USB-6008 DAQ.Can someone please explain me or e-mail me a code how can i use my digital input where i connected the push button as a counter so...

View Article

NI 9403 timing hardware or only software

I'm confused on the NI 9403 documentation is it only software timing control? The specs say the 9403 cannot route clock and timing signal --> does this mean you cannot use hardware...

View Article

Digital Output - Unwanted Reset on Lines

I am using MATLAB to change the values of my NIDAQ's digital outputs.  The outputs are sent to the digital input of another device where they are recorded.  Whenever the value of one of the output...

View Article


Generate PWM with frquency lower than 40 Hz

i'm using myRio to generate PWM signal. how can I get PWM frequency lower than 40 Hz, I would like to reach 10, 20, 30, 40 Hz

View Article


myRIO DIO level shifting from 3V to 5V

Hi,I am using a myRIO to output fast switching TTL signals to control a laser system. I used to do this using a DAQ but due to the conditions of the experiment we needed something faster so the myRIO...

View Article

Using a hamamatsu MPPC C13366-3050GD

Hi,I am building a system to detect low levels of light. Will be using a hamamatsu MPPC C13366-3050GD (http://www.hamamatsu.com/jp/en/C13366-3050GD.html)Plan to use it with a NI 9402. Please advise if...

View Article

NIDAQmx analog output C++ constant voltage

Hi, I'm currently implementing a DAQ in my C++ software which will generate the user voltage. It works fine with Matlab and I get nice changes when I put different voltages.In spite of that, when I...

View Article

Finding the correct device for CMOS control and LVDS Input

I am trying to help configure a test setup for an unconventional set of devices. I need to generate a total of 13 control signals (10-20ns minimum times)  at 0-3.3V (nominal) conditions (including a...

View Article


Button to log data in text file

I need a button to log data in text file. When button clicked then data will be written into the file. 

View Article

NI 9403 Input Impedance

Hello everybody, I'm trying to use a 9403 as digital Input to test a device.This device uses 46k4Ohm Pull-ups with 3,3VI asumed the input impedance of the Input is very large. Now i figured out, that...

View Article


Help with taking and storing date from LMT01 LPG 2 pin temperature sensor.

Hey everyone, I'm using a LMT01 temperature sensor, I need to count the number of pulses in 100ms in a pulse train, each pulse is 5us on and then 5us off (square wave) i need the total number in 100ms...

View Article

Image may be NSFW.
Clik here to view.

create digital pulse on rising edge of analog output using USB-6211

Hello, I'm working on a project that I am sending analog output, sawtooth pattern with 1024 samples @  7 usec steps. And I need to send digital pulse on each rising edge of that step (need to send 1024...

View Article


Digital pulse trigger I/O to LabView - simplest hardware available?

Hi all, Not sure if this is in the right subforum, but I thought this is closest to digital I/O since it's mostly hardware related.I have a piece of equipment in the lab that can send triggers, 5V...

View Article

GPS tracking

Hello everyone. Before I buy something that might not be useful to me, I have preferred to ask for help to you. I'm making an industrial accounting project. I need to locate the coordinates of a gecko...

View Article

Heat Exchanger Controller

I have a couple of Heat Exchangers that I'm trying to get to communicate with lab view and have been unsuccesfull so far. I have a working program that sends the correct voltage to the machine but I...

View Article