NI-845x SCL electrical level always low (USB is not connect to PC and connect...

I had got two NI USB-8451 one is working, the other isn't working, using scope,I found that the broken one's SCL electrial level always low, not familiar with SDA Pin, how can I deal with it? when i...

View Article


Cheap LEDs ?

Hello,I want to buy some cheap LEDs on Allieexpress or anywhere else, Any recommandation if someone has already bought this?

View Article


Image may be NSFW.
Clik here to view.

Which wiring is differential? (drawn diagrams)

Hello Community, I need your help wiring differential for our current input cards (NI-9253). We have also bought NI-9202 Voltage input cards which are also wired up for differential. Below are our...

View Article

Can NI USB-8452 turn 5V on and off? (using DIO)

Specification of NI-8452 link: https://www.ni.com/documentation/en/i2c-spi-interface-device/latest/specs-usb8452/specs/  Can NI USB-8452 turn 5V on and off? In specification, DIO output can be only...

View Article

sbRIO-9627 I/O Clock Output Jitter

I'm using an NI sbRIO-9627 to provide clock signals for sigma-delta ADCs. I'd like to know what the RMS jitter of the I/O clock output is, as I can't find a concrete number in the datasheet/user...

View Article


sbRIO-9627 Output Clock Jitter Filtering

We are considering using the NI sbRIO-9627 to provide a stable and low jitter clock signal (20MHz clock derived from the 40MHz internal oscillator fed to the FPGA) for sigma-delta ADC’s. This would be...

View Article

Lead Times

NI seems to make a good products, however with the lead times to get boards, I am being forced to go other directions. If this company wants to stay in business this needs to be addressed. In the time...

View Article

Need help with NI-USB6501 and inverting lines of a DI channel

Hi, I'm trying to achieve the following and not sure how to. My interface with the outside world is giving me 5V when i need to detect something as active when calling the DAQmxReadDigitalLines...

View Article


Image may be NSFW.
Clik here to view.

100kHz Variable Digital Output Pulse Train

I have to output what amounts to a Finite Non-Repeating (Variable) Digital Output Pulse with 61 Million points at 100kHz. I imagine I can't use the Finite Samples timing method but rather have to use...

View Article


Differential measurements on NI9025

Hello,I am trying to measure a differential voltage across a FET, FET is operated at 48V but the differential voltage will be less than 1V.Can I configure NI9205 as differential voltage measurement

View Article

Writing Digital Outputs in USB-6002

Trying to understand how to use Tasks and Channels to write Discrete outputs. I see where a Task encapsulates operations and information, and that one or more channels are created and assigned to a...

View Article

Image may be NSFW.
Clik here to view.

sbRIO-9627 RMC Connector Pinout Mapping

We are planning on developing a custom RMC board to use with the sbRIO-9627 however, we are uncertain about the pinout/orientation of the RMC connector, as the sbRIO-9627 user manual is not clear on...

View Article

SH68-C68-S Shielded Cable

I am using SH68-C68-S Shielded Cable  with PXI 7831R FPGA for signal acquisition. In  some of the twisted pairs (in SH68-C68-S), the DIO lines are paired with other DIO lines instead of DGND. Will it...

View Article


Image may be NSFW.
Clik here to view.

PXIe-6544 HSDIO Waveform Generator

Hi NI Community, I'm trying to use the module HSDIO PXIe-6544 to generate a clock (square wave) of a specified frequency. I found an example in the LabVIEW examples and made changes to it. This is...

View Article

Sincronización LabVIEW y Arduino

Hola!Estoy haciendo un control del temperatura con un DHT11 y arduino, para poder controlar un ventilador y un calefactor (foco). Bueno, pues ya he armado el block diagram y el codigo de arduino, y...

View Article


NI Vision Builder AI and NI myRIO-1900 can communicate?

Can the Read/Write I/O in NI Vision Builder AI be communicated with NI myRIO-1900? I want to control an alarm through NI myRIO-1900 based on the Pass/Fail result of NI Vision Builder AI. Thank you. 

View Article

NI 9401, delay in sending output signal in different channels

I was messing around with a 9401 using LabVIEW's built in digital - continuous output example vi. I noticed that for every channel there is a delay from when the vi is run and the signal actually being...

View Article


I have a C-9184 4 slot system and a 4-20ma HART sensor.

I'm trying to get output from this 4-20mA HART sensor. I'm using NI-9205 and using ai0 but and not getting any output. Should my card be different than NI9205? trying to use MAX and my input is 21mA...

View Article

Image may be NSFW.
Clik here to view.

Digital waveform output problem

Hello, my hardware is PCI 6251, 6351 and BNC-2120.I made vi that can make analog waveform signal to digital waveform signal. I have problem with digital output.In vi digital waveform graph, I can see...

View Article

How can I increase the number of digital inputs?

The goal is low latency and simultaneous button presses. It should be able to read all 100 buttons simultaneously, and rather quickly. I posted a more general question regarding my whole project, but...