NI-DAQmx

Hi all,I am trying to sample a 12bit input using sample clock and start sampling trigger. Here's how I configure the...

View Article


How to trig the measure of an analogic value on a usb-6211 in C?

Hi I am new in the control of the Ni instruments, and I am completly stuck concerning a usb-6211. I wish to acquire an analogic voltage when an interruption is detected on a digital port. Can you...

View Article


Serial VISA and MCC USB-ERB24 Compatibility Issue

Hello!  I haven't had much experience working with Digital I/O signals or VISA; however I did figure out how to control a syringe pump (Legato 270 - KD Scientific) using through VISA. I started having...

View Article

Do we have Digital to Analog converter with high current output?

Do we have Digital to Analog converter with high current output? I need 8 channels and each channel has at least 100mA current output.Thanks!

View Article

could not load file or assembly 'nationalinstruments.DAQmx, version= 9.2.40.82

Hello,I have a problem in my software deployment, using NIDAQ 6518.I get the following message when i start my software on the deployment computer:could not load file or assembly...

View Article


I2C Emulation with DIO

Hi,I have the USB-6343 and will make a I2C Emulation with 2 DIO, I2C-Emulation should control a Digital Potentiometer.Has anyone an idea or a example to this topic?Regards

View Article

problème NI usb 6211, sample rate et sample to read

Bonjour, je viens vers vous car je souhaite faire une acquisition continu d'un signal d'une entrée analogique. Sur cette entrée analogique est branchée un accéléromètre et un transducteur qui me...

View Article

DIO Port write line mask

Hello, I'm trying to port a legacy DAQ program to DAQmx, and have never used Labview Before. I have several DIO Port Writes and all of them use the "Line Mask" Input which is no longer there on the...

View Article


Grant a 3D Medal at Your Coming Important Ceremony

3D Animationappreciation to 21st Centuary automation technology, the Ability to form and gift a high-tech  3D trophy for any event is nearer than you're thinking that. The process is kind of simple;...

View Article


NI 9401 switching frequency

Hello fellow LabVIEWers, I have a problem in understanding the expression "switching frequency" in the spec of the NI 9401.If I use all eight kanals for inputs, it is stated that the switching...

View Article

NI USB-8473 Question About Configuring the Baud Rate

Hi, I am trying to set up a CAN bus monitor with the USB-8473 product.   I can not see anything.  I have configured a microcontroller-based board as a node on the CAN bus.  I need to match the timing...

View Article

FPGA IP integration

Hello,I'm trying to add a VHDL IP to an FPGA project in simulation mode,But none of outputs are movingAny help?

View Article

Specify Samples Only At Change?

No doubt a variation of this has been asked before, so my apologies but I'm unable to find anything. I am using a PCIe-6537 and trying to generate a long sequence (say 2 seconds) using C. Is there any...

View Article


PCI-DIO-32HS error FFFCB820 (-215008)

DAQmx Start task gives this unknown error. What can it mean? I am running digital acquisition task  with Burst (Output clock) with some external device, transmitting data. Alone it works fine.Then I...

View Article

NI 1722 smart camera

hi ,i am using NI 1722 smart camera but sometimes it take long time during acquire image.Is there any problems with the software or hardware?

View Article


Switching on LED using 9401

Hello, In LV 2010 version, I'm trying to just gow an LED using 9401 I/O module. I'm using Mod2/DIO1 to connect a switch and Mod2/DIO0 to connect to an LED. The switch is used as a control and LED as an...

View Article

Specify end point for Digital output using a Circular Buffer

When using DAQmx and an NI DAQ to output a digital signal using a circular buffer (the DAQs buffer). The program runs and works but when the function "DAQmx Stop Task.vi" is called to terminate the...

View Article


Help choosing hardware for lab mirco distilling fermenting plant

Hi, I have been fiddling around with LABview for a while now but i have a hard time choosing hardware for a simple slow lab scale fermenting and distilling plant. The hardware should be pc based and...

View Article

8452 SPI communication

Hello, I have made a VI to communicate get the data from my sensor when I will send the commands. But it just returning me 00000000000000000 at each time. In oscilloscope I see something getting back...

View Article

recovering audio signal from PCM stream

Hi i want to recover an audio signal from a PCM stream which is being transmitted by a third party  system  on RS 422 wires. the only information i have about the PCM stream is sampling freq...

View Article