Quantcast
Channel: Digital I/O topics
Browsing all 2167 articles
Browse latest View live

Configure routed PFI as output on PCIe-6536B using NIDAQmx C interface

I have an NI PCIe-6536B, which I am interacting with using the NIDAQmx C API and NI MAX.PFI5 takes input to the NI card. I want to route that signal to PFI1 and drive that signal out from the NI card....

View Article


Analog and Digital clock synchronization error (

I'm currently working on a project where my digital and analog outputs must be done simultaneously. I wanted to setup a basic test file in C but I keep getting an error message, namely code -200077....

View Article


NI USB-6525

Hallo , I am very new to this NI USB 6525 environment. I have installed NI MAX for USB-6525. I would like to ask you all the can somebody please recommend me how to perform test on USB-6525 initially...

View Article

NI USB-6501 and "DO.Output Drive Type" parameter

Hi all. I have a box, integrated in a TE, that houses a USB-6501 card.DI and DO are properly conditioned and can be accessed by a custom connector.A LabVIEW application controls the whole TE and, at...

View Article

Looking for Discrete Card

Hello everyoneI'm looking for a card that will have the following minimum I/O requirements:24x GND/Open 2x 28Vdc/Open Could anyone suggest me something from where I can start digging?

View Article


Need Examples using USB-8452 with C#

I would like to use the NI USB-8452 with Microsoft C# and Visual Studios 2013.I found the  NI Knowledge Base paper: "How Can I Access USB-845x API Function from a C/C++ Program?"...

View Article

Image may be NSFW.
Clik here to view.

Treiber in Installer integrieren macht probleme (NI Usb-6008 + Redlab Temp)

Hallo liebes Forum,ich schreibe zur Zeit an meiner Bachelorarbeit.Thema:Konzeption und Bau eines Lehrversuchs (...)Ich habe den Lehrversuch gebaut und mit Messtechnik vollgestopft. Soweit, so gut!Auch...

View Article

The cable model SHC68-C68-RDIO2 can be replaced by SHC68-C68-D4?

Hi Is it possible to use the cable SHC68-C68-D4 in to a NI PXIe-7821R board? Thanks,

View Article


Image may be NSFW.
Clik here to view.

How to Upgrade my Digital Thermometer Clock?

The Digital Thermometer clock used a DS1302 RTC chip which isn’t really very accurate and mine tends to lose a few minutes every month, so I started looking around to see if I could find a better...

View Article


real time binary data transmission using USRP and PSK modulation, labview...

I have been working with the student lab manual and learning materials for the USRP by Bruce A Black.Included with this are a few labview communications suite examples, showing how to BPSK/QPSK...

View Article

Digital Output 6052E BNC-2111

I am trying to generate digital signal using 6052E DAQ and BNC-2111. I used NI-MAX test panel to make sure that I can generate Digital output using this DAQ and BNC, but the problem is that the output...

View Article

Looking for Frame Grabber

We are looking fo Mateor2 Dig 64L REV.A (601version) which will be embedded in Retcam2 medical device.We once tried with Meteor2-DIG/4/L REV02 but it seems it is not compatible to each other.No matter...

View Article

LVDS from NI5782

Please tell me how to make a digital signal output from NI 5782 via AUX to the LVDS receiver. Interested in the electrical circuit connections and an example of a VI for the supply of test signals.

View Article


Compact Daq cDAQ maximum PWM outputs? PWM output module availability?

Hello.  Is the cDAQ limited to 4 hardware PWM outputs?  I realize that there are 4 counters available on cDAQ chassis and these can be accessed with a digital I/O module.  I am currently using a...

View Article

PXI-6541 Configuring Input/Output Channels

We have a test system with PXI-6541 digital waveform card that has never been used.  I'm helping the test person debug the Labview program. It appears the channels being used as inputs always have the...

View Article


9402 maximum Output Current for driving Broadcom HFBR-1521 LWL Transmitter

Hello,I would like to connect a Broadcom HFBR-1521 LWL Transmitter to the NI 9402 DIO in a cRIO-9063 cabinet.What is the maximum Output Current of the 9402?If it is below 20mA I'm going to use an...

View Article

Reboot resets NI 9476

I am using an NI-9476 module in a cDAQ system (NI cDAQ-9133 Controller) to control some pneumatic valves.  My software "environment" is Labview 2015 and Windows 7 embedded.  My problem is that when the...

View Article


PXIe 6547, inverse the reference clock (CLKIN) edges

PXIe 6547, how to inverse the reference clock (CLKIN) edges? is there any HSDIO function to inverse/control the ref clock?

View Article

PCI-1720U

Hi, I bought the PCI-1720U  analog output card . During the laboratory's investigation, due to an error,   15 volt DC connected to the output of a card channel , and then I could not get data from card...

View Article

PCI-6519 compatibility with Real Time OS (pharlab)

HiI want to buy PCI-6519. but I have two question:1) Is this card compatible with labview real time OS (Pharlab)? On the other hand, I have a real time desktop PC and I want to insert the PCI card to...

View Article
Browsing all 2167 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>